HAKKO FR-1418 Top Heater Resistance Specifications
9 Years Ago
Chris Stuber
FR-1418
The following are the nominal resistance values for the various heating elements used in the top heater of the HAKKO FR-1418
BGA
Rework System:
750W 120V - 18 Ohms
1000W 120V - 14 Ohms
1000W 230V - 56 Ohms
2000W 230V - 25.7 Ohms
Measuring the heating element resistance should be done with the heater core at room temperature and disconnected from system.
Details
Article ID:
10639
Last Modified:
9 Years Ago
Last Modified By:
Chris Stuber
Type:
INFO
Rated 1 star based on 2 votes.
Article has been viewed 2.3K times.
Options
Print Article
Comments RSS
Export As PDF
Also In This Category
What are the dimensions of the component nest on a Hakko FR-1418 SMD Rework System?
No Capture Devices Installed on this System
Restriction of Hazardous Substances (RoHS) Directive
What Hakko Products Do Not Require Calibration?
What is the maximum nozzle size for FR-1418?
Why does the top heater temperature oscillate on my HAKKO FR-1418 BGA Rework Station?
Camera image is black from the HAKKO FR-1418 BGA Rework System
What HMI version software can I use with my HAKKO FR-1418 BGA Rework System?
What is the temperature accuracy for the thermocouples used by the HAKKO FR-1418 BGA Rework System?
By using this site you agree to our
Privacy Policy
and
Terms & Conditions
. On this site we use cookies for analytics and personalisation purposes only. Click OK to accept cookies.
OK