Search

HakkoUSA Knowledge Base

FR-811 Basic / Demo Parameter settings

Soldering

In this article you will find Basic / Demo parameters for the FR-811 Hot air rework station 

*** NOTE *** PLEASE SET FR-811 TO TC LINK MODE 

***Please note that the first (3)  Demo Parameters are general guidelines for reference  , Actual settings will defer Depending on " Nozzle being used , type of solder , and location of T/C "  . 

 

LIGHT DEMO PARAMETERS ARE AS FOLLOWS : 

 TIMER : OPENED 

                    ZONE            RAMP           TEMP           TIMER         AIR           VACUUM    

ZONE1  :      ON                3'C/S             120'C            30S            30%          OFF

ZONE2  :      ON                 3'C/S             180'C           30S             30%          OFF

ZONE3  :      ON                 3'C/S             260'C           10S            30%           OFF

ZONE4  :     OFF               --'C/S             400'C            30S            50%           OFF

ZONE5  :     OFF               --'C/S             500'C            30S            50%           OFF

ZONE6  :     OFF               --'C/S             600'C            30S            50%           OFF

BOTTOM :   MODE 

                    POWER

PREZONE :

                    ZONE           RAMP           TEMP        POWER        TIMER                         
                    OFF              --'C/S             150'C         50%               150S

 

MEDIUM DEMO PARAMETERS ARE AS FOLLOWS : 

 TIMER : OPENED 

                    ZONE            RAMP           TEMP           TIMER         AIR           VACUUM    

ZONE1  :      ON                3'C/S            120'C            40S            40%         OFF

ZONE2  :      ON                 3'C/S            160'C            50S            40%          OFF

ZONE3  :      ON                 3'C/S             200'C           30S            40%          OFF

ZONE4  :      ON                 3'C/S             260'C           15S            40%          OFF

ZONE5  :      OFF              --'C/S              500'C           10S            50%          OFF

ZONE6  :      OFF              --'C/S              600'C           10S            50%          OFF

BOTTOM :   MODE 

                    POWER

PREZONE :

                    ZONE           RAMP           TEMP        POWER        TIMER                         
                    OFF              --'C/S             150'C         50%               150S     

 

 HEAVY DEMO PARAMETERS ARE AS FOLLOWS : 

 TIMER : OPENED 

                    ZONE            RAMP           TEMP           TIMER         AIR           VACUUM    

ZONE1  :      ON               3'C/S             120'C           40S           50%           OFF

ZONE2  :      ON                3'C/S             160'C           50S            50%          OFF

ZONE3  :      ON                3'C/S             190'C           30S            50%          OFF

ZONE4  :      ON                3'C/S             200'C           30S             50%         OFF

ZONE5  :      ON                3'C/S             260'C           15S            50%          OFF

ZONE6  :      OFF              --'C/S             600'C          10S             50%          OFF

BOTTOM :   MODE 

                    TC

PREZONE :

                    ZONE           RAMP           TEMP        POWER        TIMER                         
                    ON              --'C/S             130'C         50%               150S       

 

*** The following Install / Remove Demo's are performed with a standard N51 BGA type nozzle

999-133 INSTALL DEMO PARAMETERS ARE AS FOLLOWS : 

 TIMER : OPENED 

                    ZONE            RAMP           TEMP           TIMER         AIR           VACUUM    

ZONE1  :      ON                3'C/S             170'C            40S            50%          OFF

ZONE2  :      ON                 3'C/S             210'C           50S             50%           OFF

ZONE3  :      ON                 3'C/S             230'C           30S             50%           OFF

ZONE4  :      ON                 3'C/S             270'C           15S             50%           OFF

ZONE5  :      OFF              --'C/S              500'C           10S             50%           OFF

ZONE6  :      OFF              --'C/S              600'C           10S             50%          OFF

BOTTOM :   MODE 

                    POWER

PREZONE :

                    ZONE           RAMP           TEMP        POWER        TIMER                         
                    OFF              --'C/S             150'C         50%               150S        

999-133 REMOVAL DEMO PARAMETERS ARE AS FOLLOWS : 

 TIMER : OPENED 

                    ZONE            RAMP           TEMP           TIMER         AIR           VACUUM    

ZONE1  :      ON               3'C/S              120'C            40S            40%          ON

ZONE2  :      ON                3'C/S              160'C            50S            40%          ON

ZONE3  :      ON                 3'C/S             190'C            30S            40%          ON

ZONE4  :      ON                 3'C/S             200'C            15S            40%          ON

ZONE5  :      OFF               --'C/S             260'C            10S            50%          OFF

ZONE6  :      OFF               --'C/S             600'C            10S            50%          OFF

BOTTOM :   MODE 

                    POWER

PREZONE :

                    ZONE           RAMP           TEMP        POWER        TIMER                         
                    OFF              --'C/S             150'C         50%               150S        

 

       

 

Details
Article ID: 11851
Last Modified: 4 Years Ago
Last Modified By: Kyle
Type: INFO
Rated 3 stars based on 2 votes.
Article has been viewed 2K times.