In this article you will find Basic / Demo parameters for the FR-811 Hot air rework station
*** NOTE *** PLEASE SET FR-811 TO TC LINK MODE
***Please note that the first (3) Demo Parameters are general guidelines for reference , Actual settings will defer Depending on " Nozzle being used , type of solder , and location of T/C " .
LIGHT DEMO PARAMETERS ARE AS FOLLOWS :
TIMER : OPENED
ZONE RAMP TEMP TIMER AIR VACUUM
ZONE1 : ON 3'C/S 120'C 30S 30% OFF
ZONE2 : ON 3'C/S 180'C 30S 30% OFF
ZONE3 : ON 3'C/S 260'C 10S 30% OFF
ZONE4 : OFF --'C/S 400'C 30S 50% OFF
ZONE5 : OFF --'C/S 500'C 30S 50% OFF
ZONE6 : OFF --'C/S 600'C 30S 50% OFF
BOTTOM : MODE
POWER
PREZONE :
ZONE RAMP TEMP POWER TIMER
OFF --'C/S 150'C 50% 150S
MEDIUM DEMO PARAMETERS ARE AS FOLLOWS :
TIMER : OPENED
ZONE RAMP TEMP TIMER AIR VACUUM
ZONE1 : ON 3'C/S 120'C 40S 40% OFF
ZONE2 : ON 3'C/S 160'C 50S 40% OFF
ZONE3 : ON 3'C/S 200'C 30S 40% OFF
ZONE4 : ON 3'C/S 260'C 15S 40% OFF
ZONE5 : OFF --'C/S 500'C 10S 50% OFF
ZONE6 : OFF --'C/S 600'C 10S 50% OFF
BOTTOM : MODE
POWER
PREZONE :
ZONE RAMP TEMP POWER TIMER
OFF --'C/S 150'C 50% 150S
HEAVY DEMO PARAMETERS ARE AS FOLLOWS :
TIMER : OPENED
ZONE RAMP TEMP TIMER AIR VACUUM
ZONE1 : ON 3'C/S 120'C 40S 50% OFF
ZONE2 : ON 3'C/S 160'C 50S 50% OFF
ZONE3 : ON 3'C/S 190'C 30S 50% OFF
ZONE4 : ON 3'C/S 200'C 30S 50% OFF
ZONE5 : ON 3'C/S 260'C 15S 50% OFF
ZONE6 : OFF --'C/S 600'C 10S 50% OFF
BOTTOM : MODE
TC
PREZONE :
ZONE RAMP TEMP POWER TIMER
ON --'C/S 130'C 50% 150S
*** The following Install / Remove Demo's are performed with a standard N51 BGA type nozzle .
999-133 INSTALL DEMO PARAMETERS ARE AS FOLLOWS :
TIMER : OPENED
ZONE RAMP TEMP TIMER AIR VACUUM
ZONE1 : ON 3'C/S 170'C 40S 50% OFF
ZONE2 : ON 3'C/S 210'C 50S 50% OFF
ZONE3 : ON 3'C/S 230'C 30S 50% OFF
ZONE4 : ON 3'C/S 270'C 15S 50% OFF
ZONE5 : OFF --'C/S 500'C 10S 50% OFF
ZONE6 : OFF --'C/S 600'C 10S 50% OFF
BOTTOM : MODE
POWER
PREZONE :
ZONE RAMP TEMP POWER TIMER
OFF --'C/S 150'C 50% 150S
999-133 REMOVAL DEMO PARAMETERS ARE AS FOLLOWS :
TIMER : OPENED
ZONE RAMP TEMP TIMER AIR VACUUM
ZONE1 : ON 3'C/S 120'C 40S 40% ON
ZONE2 : ON 3'C/S 160'C 50S 40% ON
ZONE3 : ON 3'C/S 190'C 30S 40% ON
ZONE4 : ON 3'C/S 200'C 15S 40% ON
ZONE5 : OFF --'C/S 260'C 10S 50% OFF
ZONE6 : OFF --'C/S 600'C 10S 50% OFF
BOTTOM : MODE
POWER
PREZONE :
ZONE RAMP TEMP POWER TIMER
OFF --'C/S 150'C 50% 150S