HAKKO FR-1418 Top Heater Resistance Specifications


Chris Stuber
FR-1418

The following are the nominal resistance values for the various heating elements used in the top heater of the HAKKO FR-1418 BGA Rework System:
  • 750W 120V - 18 Ohms
  • 1000W 120V - 14 Ohms
  • 1000W 230V - 56 Ohms
  • 2000W 230V - 25.7 Ohms
Measuring the heating element resistance should be done with the heater core at room temperature and disconnected from system.