Why do the LED lights on by FR-1418 BGA Rework System flicker/blink?


The intensity of the LED lighting used on the Hakko FR-1418 BGA Rework System is controlled with a volume control in the circuit.  At select positions there may be a slight flicker that may or may not be noticeable.  This is normal and will not affect the operation or accuracy of the system.

If the flicker appears to be longer in duration and appears to be the result of an entire row of LED lights turning off for a short interval, the issue may be a faulty LED component.  The LED lighting boards consist of 3 rows of LED lights where each of the three rows are in series.  If there is an intermittent LED in the row, the entire row may flicker and will be more noticeable.